Two Dealership EV Fires in Three Days: One Hospitalized Two Workers, the Other Held Firefighters for 17 Hours

A battery pack in thermal runaway sent two workers to the hospital on Monday, Oct. 12, at a car dealership on South Colony Road in Wallingford, Conn. Three days earlier, a fire at a Cadillac dealer in Fort Worth, Texas, had started a burn that lasted 17 hours and 33 minutes. One fire was in a garage with people in it. The other was on a lot full of cars. That difference is most of what the two incidents have to teach.

What Wallingford officials have said

Firefighters were called to the garage around 11:45 a.m., according to WFSB, and found heavy smoke and a battery pack in thermal runaway. One worker was taken to the hospital with burns and a second with smoke inhalation. Fire Engineering, relaying a Journal Inquirer report, says the pack short-circuited and ignited, that crews knocked the fire down inside the building, and that they then removed the pack so it could not spread the fire. Wallingford hazmat technicians and the Connecticut Department of Energy and Environmental Protection responded because of the chemicals in the packs, and Meriden firefighters, Eversource, and state police assisted.

A WTNH headline calls it a Porsche dealership. The other reports I could open do not name the dealer or the vehicle, and none says what the two workers were doing when the pack failed. No cause has been released.

Seventeen hours at Frank Kent Cadillac

Fort Worth firefighters were dispatched to Frank Kent Cadillac, in the 3500 block of West Loop 820, around 5 p.m. on Friday, Oct. 9. The incident ended around 10:30 a.m. Saturday, according to Fire Engineering. Six electric SUVs were destroyed and at least two others were damaged. Nobody was hurt, and the cause is under investigation. The department said EVs can burn much hotter than an average fire and that, in its words, “The vehicles are deliberately built not to let water in.” Crews covered the burning SUVs with fire blankets and moved other vehicles out of the fire’s path. The Auto Wire’s earlier report on the Fort Worth fire has the department’s timeline and the GM recall question.

Why a sealed pack is hard to put out

The seal is what lets a pack survive car washes, flooded intersections, and slush kicked up by the front tires. When one cell overheats and passes the heat to its neighbors, which is thermal runaway, the same seal keeps a hose stream away from the cells that are burning. Crews can cool the outside for hours, and a pack that looks finished can restart.

A dealership adds two problems of its own. Inventory is parked close together, so a burning vehicle has neighbors to ignite. A service garage puts technicians within arm’s reach of packs, some of which were brought in because something is wrong with them. In Wallingford, the injuries were burns and smoke inhalation inside the building.

Fire blankets stop the flames and trap the gas

Blankets are the tool Fort Worth crews used, and they are the subject of a federal advisory. In June 2025 the U.S. Fire Administration passed along a notice from the Fire Protection Research Foundation, the research affiliate of the National Fire Protection Association, and UL Research Institutes’ Fire Safety Research Institute. Their experiments found that a blanket put out the visible flames by cutting off oxygen, while thermal runaway continued underneath and flammable gases built up. In some tests that buildup created an explosion risk for firefighters working near the vehicle, especially when air got back in. Washington crews celebrated their first successful use of an EV blanket the same year the notice went out…